Parker PFX15 | Formerly 2248D to 2440D | WP 1500 Bar

Parker PFX15 | Formerly 2248D to 2440D | WP 1500 Bar

Parker PFX15 | Formerly 2248D to 2440D | WP 1500 Bar


Datasheet Download

 

PFX15

Description

Parker PFX15 | WP 1500 Bar | Tube cleaning applications
DN | mm | inch | size
mm
bar | psi
bar | psi
mm
kg/m
Legacy part number
PFX15-025-PL4 | 4.0 | 5/32 | -0257.91500 | 21,7503750 | 54,375750.112248D-025V32
2248D-025V32-TC
2248D-025V62-HT-TC
PFX15-03-PL5 | 4.9 | 3/16 | -039.51500 | 21,7503750 | 54,375950.142248D-03V32
2248D-03V32-TC
2248D-03V62-HT-TC
PFX15-05-PL8 | 8.1 | 5/16 | -0514.61500 | 21,7503750 | 54,3751750.442440D-05V32
2440D-05V32-TC
2440D-05V62-HT-TC
Applications

High pressure service for tube cleaning applications such as heat exchanging in the chemical and oil refining industries. Designed to have the smallest outer diameter available in the market. Also suitable for hydraulic bolt tensioning equipment, test rigs and general industrial cleaning. Qualified for water temperatures up to 100°C, making it suitable for hot water systems.

Features

– Compact outside diameter for tight spaces
– Resistant against hydrolysis, ozone and UV radiation
– Qualified to 100°C water temperature, suitable for hot water systems
– PL = Prolance: tough cover qualified with both standard and compact Prolance fitting series
– In accordance with ISO 23384 and DIN EN 1829-2
– Design factor greater than 2:1

Construction

Core tube: Polyoxymethylene.
Pressure reinforcement: Two to four spiral layers of maximum tensile wire.
Cover: Polyamide, Prolance tough cover.
Colour: Blue.

Temperature Range

-40°C to +100°C